SolaX Power Network Technology (Zhejiang) Co.,Ltd.
x3-hyb-g4-pro-2
x3-hyb-g4-pro-1
x3-hyb-g4-pro-3
Three Phase Inverter

X3 HYBRID G4 PRO

X3 HYBRID G4 PRO

4kW / 5kW / 6kW / 8kW


10kW / 12kW / 15kW


Smart Energy

  • V2X ready for smart home energy integration

  • Intuitive management with Smart Schedule, Scene,  and TOU

  • VPP ready, supporting FCAS, 2030.5, and OpenADR

  • Wireless meter compatible for convenient setup


Economically Efficient

  • 20A DC input per MPPT with 3 trackers

  • 200% PV oversizing and 110% AC overloading

  • Ultra-wide MPPT range of 110-950V


Flexible Expansion

  • Dual independent battery ports and 2-in-1 function for  effortless expansion

  • Additional ports for simplified wiring and installation

  • Functional and stylish wiring cover

  • Microgrid and generator modes for versatile operations


Safe and Reliable

  • Rapid shutdown function compatible

  • SPD-Ⅱ protection on both DC/AC sides, AFCI optional

  • 10s 200% EPS output with ≤10ms UPS level switch time


Why X3 HYBRID G4 PRO

X3-HYB-G4 PRO offers flexible expansion with dual independent battery ports and versatile microgrid and generator modes. It ensures safety with rapid shutdown compatibility, SPD-II protection, and 10s 200% EPS output with fast UPS-level switch time. Smart energy management is enabled with V2X readiness, intuitive controls, and VPP compatibility. Economically, it supports 200% PV oversizing, 110% AC overloading, and features a 20A DC input per MPPT with 3 trackers, all within an ultra-wide MPPT range of 110-950V.


X3 HYD G4 PRO 4.0P
X3 HYD G4 PRO 5.0P
X3 HYD G4 PRO 6.0P
X3 HYD G4 PRO 8.0P
ParameterValue
Max. recommended PV array power [Wp]8000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]4000
Max. apparent AC power [VA]4400
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)5.8
Max. AC current [A]6.7
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]8000
Nominal AC current [A]11.6
Max. AC current [A]12.2


ParameterValue
Max. recommended PV array power [Wp]8000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]4000
Max. apparent AC power [VA]4400
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)5.8
Max. AC current [A]6.7
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]8000
Nominal AC current [A]11.6
Max. AC current [A]12.2


ParameterValue
Max. recommended PV array power [Wp]10000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker2 (1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]5000 (AS 4777 4999)
Max. apparent AC power [VA]5500 (AS 4777 4999)
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)7.2
Max. AC current [A]8.4
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]10000
Nominal AC current [A]14.5
Max. AC current [A]15.2


ParameterValue
Max. recommended PV array power [Wp]16000
Max. input voltage [V]1000
Nominal DC operating voltage [V]650
No. of MPP trackers / Strings per MPP tracker3 (1 / 1 / 1)
Max. input current (input 1 / input 2 / input 3) [A]PV1:20 / PV2:20 / PV3:20
Max. short circuit current (input 1 / input 2 / input 3) [A]PV1:25 / PV2:25 / PV3:25
MPPT operating voltage range [V]110-950
Start output voltage [V]140
Nominal AC power [VA]8000
Max. apparent AC power [VA]8800
Rated grid voltage (AC voltage range) [V]3P4W, 400 / 380
Rated grid frequency [Hz]50 / 60
Nominal AC current [A] (at 230V)11.6
Max. AC current [A]13.4
Displacement power factor~1 (Adjustable from 0.8 leading to 0.8 lagging)
Total harmonic distortion (THDi, rated power) [%]<3
Nominal AC power [VA]16000
Nominal AC current [A]23.2
Max. AC current [A]24.3


Related Products