800W/ 900W / 1000W / 1200W
Reactive power control
Rapid shutdown function
Easy to install and maintain
Support micro-grid solution
Support AC coupling solution
Support 1-phase microinverter integration into 3-phase power grids
Max. 1200VA output power
Max. 20A DC input current
Two MPPT channels, small size, light weight
Built-in industrial grade Wi-Fi module
Safety protection relay integrated
IP67 protection class
Experience the next generation of solar energy with the SolaX X1 Micro Inverter 2 in 1. Designed for residential and small-scale commercial applications, this compact and lightweight inverter offers a maximum output of 1200VA and 20A DC input current, ensuring efficient energy conversion. With two MPPT channels, it optimizes performance from your solar panels. The SolaX X1Micro Inverter 2 in 1 is not just efficient; it's safe, featuring an IP67 rating and a built-in industrial-grade Wi-Fi module for seamless connectivity. Its intelligent design includes reactive power control and a rapid shutdown function, making it easy to install and maintain. Plus, with flexible adaptability to support micro-grids, AC coupling, and integration into 3-phase power grids, the X1 Micro Inverter is the smart choice for your solar power needs.
DC INPUT | |
Specification | 240 ~ 470+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 ×15 A |
Max. input short circuit current Isc | 2 × 20 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 750 VA |
Maximum continuous output power | 750 VA |
Maximum continuous output current | 3.41 A @220 V |
3.26 A @230 V | |
3.13 A @240 V | |
Rated grid voltage/range | 1 / N / PE, 220/230/240 V |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | 50 卤 5 Hz / 60 卤 5 Hz |
Maximum units per 10AWG branch* | 8 @220 V |
8 @230 V | |
8 @240 V | |
Maximum units per 12AWG branch* | 6 @220 V |
6 @230 V | |
6 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |
DC INPUT | |
Specification | 320 ~ 540+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 × 16 A |
Max. input short circuit current Isc | 2 × 25 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 800 VA |
Maximum continuous output power | 800 VA |
Maximum continuous output current | 3.64 A @220 V |
3.48 A @230 V | |
3.34 A @240 V | |
Rated grid voltage/range | |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | |
Maximum units per 10AWG branch* | 7 @220 V |
8 @230 V | |
8 @240 V | |
Maximum units per 12AWG branch* | 5 @220 V |
6 @230 V | |
6 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |
DC INPUT | |
Specification | 360 ~ 600+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 脳 16 A |
Max. input short circuit current Isc | 2 脳 25 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 900 VA |
Maximum continuous output power | 900 VA |
Maximum continuous output current | 4.10 A @220 V |
3.92 A @230 V | |
3.75 A @240 V | |
Rated grid voltage/range | |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | |
Maximum units per 10AWG branch* | 6 @220 V |
7 @230 V | |
7 @240 V | |
Maximum units per 12AWG branch* | 5 @220 V |
5 @230 V | |
5 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |
DC INPUT | |
Specification | 360 ~ 600+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 × 20 A |
Max. input short circuit current Isc | 2 × 25 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 1000 VA |
Maximum continuous output power | 1000 VA |
Maximum continuous output current | 4.55 A @220 V |
4.35 A @230 V | |
4.17 A @240 V | |
Rated grid voltage/range | |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | |
Maximum units per 10AWG branch* | 6 @220 V |
6 @230 V | |
6 @240 V | |
Maximum units per 12AWG branch* | 4 @220 V |
5 @230 V | |
5 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |
DC INPUT | |
Specification | 400 ~ 670+ W |
Max. PV input voltage | 60 V |
MPPT voltage range | 22 ~ 60 V |
Start-up voltage | 22 V |
Max. PV input current | 2 × 20 A |
Max. input short circuit current Isc | 2 × 25 A |
No. of MPPT trackers | 2 |
Strings per MPPT tracker | 1 |
AC OUTPUT | |
Specification | 1200 VA |
Maximum continuous output power | 1200 VA |
Maximum continuous output current | 5.46 A @220 V |
5.22 A @230 V | |
4.73 A @240 V | |
Rated grid voltage/range | |
Nominal AC voltage range | 180 ~ 264 V |
Nominal AC frequency | 50 Hz / 60 Hz |
AC frequency / range | |
Maximum units per 10AWG branch* | 5 @220 V |
5 @230 V | |
5 @240 V | |
Maximum units per 12AWG branch* | 3 @220 V |
4 @230 V | |
4 @240 V | |
Power Factor range | ~ 1 (0.8 lagging to 0.8 leading) |
THDi (Rated power) | < 3% |
EFFICIENCY | |
Max. efficiency | 96.50% |
Nominal MPPT efficiency | 99.50% |
Night power consumption | < 40 mW |